Description:
Turbo-Seal is a single component, highly elastomeric polymer rubber infused with special adhesives.
Turbo-Seal is ideally suited for waterproofing below grade structures. Due to its superior flexibility, adhesiveness and self-sealing characteristics.
Turbo-Seal is highly effective in repairing and restoring damaged waterproofing membrane systems.
Turbo-Seal can applied by rotor/stator pump and or spray equipment.
|
|
Features:
|
|
Benefits:
|
- Adhesive in wet conditions, active water leaks, and on surfaces with foreign materials
- Partial bentonite composition
- Remains as a flexible gel. Durable to vibration and continous movement.
- One component. No mixing of chemicals, easy to apply, safe, easily stored and transported.
- High solids content, solvent free made from recycled materials.
- Durable. Chemically resistant, resistant to freeze/thaw cycling, dry/wet cycling.
|
|
- Ease of application and effectiveness.
- Seeks out leaks and stops them.
- Waterproofing is maintained. No loss of adgesion or separation.
- Cost-effective, reduce labour, save time, fewer mistakes in application.
- Non-toxic, non-flamable, Safe application.
- Effective in many different types of enviroments.
|
|
Uses:
Turbo-Seal is applied to any below grade structure. Turbo-Seal can be applied to moist imperfect concrete surfaces. Preventative sealing is also applicable. Suitable applications include the following types of underground structures:
- Tunnels
- Underground Garages
- Water Tanks
- Septic Tanks
- Concrete Reinforced Levies
- Subway tunnels
Areas of application include:
- Shrinkage Cracks
- Moving Joints
- Pipe Penetrations
- Settlement Cracks
- Construction Joints
- Joints in Precast Concrete
- Segments
- Expansion Joints
Turbo-Seal can be injected into leaking areas after drilling to the damaged waterproofing layer restoring its integrity |
|
Packaging:
Turbo-Seal is packaged in 20L (5.3 Gallon) buckets. |
|
Injection Yield:
2.25 ft2/gallon at 7/10 wet thickness 4.00 ft2/gallon at 2/5 wet thickness |
|
Coverage:
Apply evenly a coat of Turbo-Seal at a rate of 2.0mm (+/- .05mm). Reinforce corners, concrete joints, expansion joints and pipe circumference with 25cm wide Turbo Sheet. |
|
Transportation:
Turbo-Seal is classified as a DOT non-hazardous material. |
|
Shelf Life:
Indefinite, when stored according to recommended storage guidelines. |
|
Technical Data Composition:
Turbo-Seal is a polymer rubber infused with special adhesives. |
|
Testing:
- ASTM D1353-03
- ASTM D2202-00
- ASTM D5329-04
- ASTM D56-05
- ASTM D36-00
- ASTM D2196-99
- CGSB 37.5-M89
|
|
Typical Properties:
Property |
Value |
pH |
7.5 ~ 8.0 |
Specific Gravity |
1.1 ~ 1.3 |
Freezing Point |
Below -25* |
Softening Point |
Below 30* |
Physical State |
Liquid |
Appearance |
Black |
Viscosity |
3,600,000 Cps |
Flash Point |
> 200* |
|
|
Turbo Seal - Test Data :
Property |
Results |
Test Method |
Solids Content |
75% |
ASTM D1353 |
Flow |
113 ± 4mm |
ASTM D2202 |
Penetration, in mm |
28 ± 0.8mm |
ASTM D5319 sec. 6 |
Flash Point |
No observable flash point |
ASTM D56 |
Toughness |
1.64 ± 0.15 lbs |
CGSB 37.50 - M89 |
Enlongation |
14.93 ± 1.82 inches |
CGSB 37.50 - M89 |
Energy to Break |
11.70 ± 1.08 in-lbs |
CGSB 37.50 - M89 |
Adhesion |
Rating of 1 (Excellent) |
CGSB 37.50 - M89 |
Softening |
Below 30¡C |
ASTM D36 |
Viscosity |
3,600,000 CPS @ 72¡ F |
ASTM D2196 |
Water Absorption |
Gain 7 ± 3.2 gr. |
CGSB 37.50 - M89 |
Low Temperature Flexibility |
No cracks |
CGSB 37.50 - M89 |
pH |
7.71 |
|
Results shown are not intended as performance criteria for on-site installed material. |
|
Turbo Sheet - Test Data:
Property |
Results |
Test Method |
Thickness mil. +/- (mm) |
60 (1.5) |
|
Tensile strength |
425 |
ASTM D412 psi |
Tensile strength Polyester reinforcement |
3200 |
ASTM D412 psi. min. |
Elongation |
500% |
ASTM D412 (%) |
Permeance |
0.003 |
ASTM E96B (max) |
Puncture resistance |
0.003 |
ASTM E154, lb (365) |
Pliability |
passes |
ASTM D146 |
Tensile Strength |
600 (4.1) min. |
ASTM D412, psi (Mpa) |
Color |
Black |
|
Water Absorption |
0.23 |
|
Exposure to fungi In soil for 16 weeks |
unaffected |
|
Resistance to hydrostatic Head (feet of water) |
150 |
|
Results shown are not intended as performance criteria for on-site installed material. |
|
|
How to Apply Turbo-Seal AS:
Equipment
Turbo-Seal can be applied with a rotor stator pump or spray equipment
Attachment of Turbo Sheet
Apply sheet membrane from low point to high point across fall lines so the laps shed water on horizontal surfaces. Lay membrane tack side down on coated surface. Pull the membrane tight and light broom or squeegee the membrane as it comes in contact with the coated surface. Overlap the side laps a minimum of 2″. (51mm.) Pressure roll the side laps to complete the monothilic system.For injection applications, use an injection pipe with an outer diameter of 5/8″. A hammer drill will be sufficient for most applications.
Preparation
Check the thickness of the concrete. Drill 5/8″ diameter holes to the waterproofing layer at 3.25′ intervals.Install the injection packers. For most applications, an injection pipe with an outer diameter of 5/8″ and a packer are used to make an injection opening and inspection holes at 3.25′ intervals.
Injection
Inject Turbo-Seal slowly at low pressure and continue injecting until counter flow from other drilled holes is seen. Remove the injection pipe from the drilled hole that Turbo-Seal has counter flowed through. Fill the hole with non-woven cloth and polymer mortar. If multiple locations have been drilled, repeat process as necessary.Some applications may require an initial application of polyurethane or other material to fill excessive voids.
Clean Up
Dab excess Turbo-Seal off of the pump with a cloth. Additional cleaning can be done with a thinner.
Health and Safety
Avoid contact with skin and eyes. Wear suitable gloves and safety glasses. See MSDS. |
|